Lesson 1

Your first scheme

An open pipe blowing air from a compressor — the simplest consumer there is, and one of the most expensive. Place two items, join them, type in a handful of numbers and see what that pipe costs a year.

Time about 15 minutes You need EasyCAS with its catalog installed You finish with a calculated .gf9 file

Every number you need is given in the lesson, and so is every number the program should give back. If your results match the tables, the scheme is right; if they do not, the difference tells you which input to look at.

  1. Set the units

    Open the Units tab on the right panel. The figures in this lesson are in the units below — set the lists to them before you type anything, so that a 4 means 4 mm and not 4 ft. At the top of the tab, Input units must be on As output: then what you type is read in the same units the results are shown in. Original would take every number in the unit written on the item's own card.

    ListChoose
    Air consumptionL/min
    Pressurebar
    Mass flowkg/s
    Weightkg
    Lengthmm
    ForceN
    Temperature°C
    Air costNm³
    Currency€

    Choosing any list by hand turns System into Custom; that is expected. The lists not named here (Velocity, Capacity) do not matter for this lesson.

    The Units tab set for this lesson.

    Air flow is shown in two scales from the same list: an actual flow L/min and a normal flow NL/min — the same air brought to normal pressure and temperature. You will see both in the results.

  2. Place the open pipe

    Open the Items tab. The tree is built from the Elements folder next to the program: every subfolder is a branch, every symbol a leaf. Type blow in the Filter box above the tree — the branches with nothing matching are hidden, the rest open on their own.

    The catalog narrowed to the open pipe.

    Click blowing_tube under # Generic elements #. It stays selected — the sheet is now in placing mode. Click on the right half of the sheet and the item is dropped there.

    A generic element has no catalog data of its own: you describe it with your own numbers. That is exactly what we want for a first lesson — nothing in the result comes from a card you cannot see.

  3. Place the compressor

    Type compressor in the filter, click compressor under # Generic elements #, then click the sheet well to the left of the pipe. Leave a hand's width between them — the connection needs somewhere to run.

    While a tree entry is selected every click on the sheet drops another copy. To go back to normal editing, click the selected entry again.

    Two items on the sheet, not yet joined.

    Check

    Both symbols sit on the sheet and neither is selected. If one landed in the wrong place, drag it; if you dropped a third copy by accident, Ctrl+Z.

  4. Join them

    Point at the compressor. The cursor turns into a target and the connection points of the object light up: red is an outlet, green an inlet, yellow a false connector. Press the left button on the red outlet of the compressor, drag to the green inlet of the pipe and release.

    Dragging from the outlet of the compressor to the inlet of the pipe.

    The dots are coloured by kind, not by state, and they show on the object under the pointer and on the selected one. Once joined, a point is drawn as a small dot on the line.

    The line is routed on its own: an orthogonal path with the fewest bends, around anything in the way. You can also release the button over the body of the item instead of over a dot — the program takes the first free point of the matching kind.

    A connection is a drawing, not a pipe: it carries air with no loss. When the length and the bore of a line matter, you put a pipe item into it — lessons 6 and 7 do that.

  5. Describe the pipe

    Click the pipe and open the Item tab. Three rows are green — those are yours to fill in. Click the value cell, type, press Enter:

    RowValueUnit
    Diameter4mm bore of the pipe end
    Length100mm not used in the result, but the row must be filled
    Pin6bar gauge pressure at the pipe
    The open pipe described by three numbers.

    The table is colour-coded, and the colour tells you who owns each row:

    ColourRowWhat to do with it
    BlackCatalog data Comes with the item. To change it, place a different item.
    GreenYour input Click the value cell and type, or pick from the list.
    BlueCalculated result Rewritten at every calculation. Empty until you run one.
    Dark redOut of range, or did not converge Look at this row first when a result surprises you.

    Pressures on cards and in the Item table are gauge — above atmosphere, as a pressure gauge shows them.

  6. Set the conditions the plant works under

    Open the Input parameters tab and enter:

    FieldValue
    Normal temperature (C)20
    Ambient temperature (C)20 same as normal — makes the hand check below easy
    Pressure of air (Bar)6 the pressure the air cost below was quoted at
    Compressed air cost (€/nm3)0.024
    Hours per day8
    Days per year240 8 × 240 = 1920 hours a year
    Normal pressure (Bar)1
    Electricity cost (€/kWh)0.13
    Carbon intensity (gCO2/kWh)400

    Leave the other fields as they are: the open pipe does not use them.

    Input parameters — the ground the results stand on.

    Look at the labels. Every pressure field must show its unit in brackets — Pressure of air (Bar), Normal pressure (Bar). Empty brackets mean the number is taken as pascals, and every flow in normal units comes out a hundred thousand times too large.

    Pressure of air is not the pressure the compressor makes — the calculation finds that itself. It is the pressure at which the compressed air cost was quoted: air delivered at a lower pressure costs less, at a higher pressure more.

  7. Calculate and read the pipe

    Press Calculate. In design mode EasyCAS works from the consumers back to the compressor: it takes what each consumer needs and finds the flow and pressure the compressor has to deliver. Click the pipe — blue rows have appeared under your green ones:

    RowExpectedUnit
    m0.0208kg/s mass flow
    F8.3257N blowing force
    Qn1048.25NL/min normal flow — what the compressor must deliver
    Q149.75L/min actual flow at 6 bar
    The open pipe after the first calculation.

    Check by hand

    Q and Qn are the same air at two pressures. At equal temperatures they differ by the ratio of absolute pressures: (6 + 1) / 1 = 7, and 149.75 × 7 = 1048.25. Last-digit differences are rounding; anything bigger means a unit or an input differs from the tables above.

    An open pipe chokes: the air leaves it at the speed of sound, so the flow depends only on the bore and the pressure. 4 mm at 6 bar is about one normal cubic metre a minute — roughly what a 7 kW compressor delivers, spent on a single pipe end.

    One more row sits under the results. ↔ Count of analog Pistols is a recommendation: the number of blow guns in your catalog that give at least the same force (26 with the standard catalog — yours may differ). The ↔ means the row opens a list; lesson 3 uses it. The status bar now reads Recommendations: 1 — that is this row. There are no errors and no warnings in this scheme: if the status bar shows one, an input differs from the tables above. Lesson 8 is about reading these counters.

  8. Read what it costs

    Click the compressor. Its rows are the bill for everything downstream of it — here, the one pipe:

    RowExpectedUnit
    Pout6bar equals Pin of the pipe: the connection has no loss
    Qn1048.25NL/min equals Qn of the pipe
    Q149.75L/min
    New unit cost0.024€/Nm³ Pout equals Pressure of air, so the price is unchanged
    Cs2898.2€ cost of the air a year
    Electricity consumption22293.9 kWha year
    CO28917.55kg a year
    What the compressor delivers, and what it costs.

    Check by hand

    1048.25 NL/min is 62.9 Nm³/h. Over 1920 hours that is 120 758 Nm³, and at 0.024 €/Nm³ it costs 2898.2 €. Divided by the electricity price, 2898.2 / 0.13 = 22 294 kWh; at 400 g/kWh that is 8.9 tonnes of CO2.

    The top row of the compressor, ↔ Compressor selection, opens the window where a real machine is chosen for this demand. Leave it for now.

    Cost of air is not a decoration. Energy, money and CO2 in every later report come from the Input parameters tab. Enter what the customer actually pays, or leave the figure out of the report.

  9. Change one number

    Most open pipes run at full network pressure because nobody ever turned them down. Click the pipe, set Pin to 4 and press Calculate again:

    RowPin 6 barPin 4 barUnit
    F, pipe8.32575.53 N
    Qn, pipe1048.25748.75 NL/min
    Q, pipe149.75149.75 L/min
    New unit cost, compressor0.024 0.0188€/Nm³
    Cs, compressor2898.2≈ 1622 €

    Two things happened. The pipe passes less air — Qn falls in step with the absolute pressure, 5/7 of what it was, while Q at the pipe stays the same because the outlet is still choked. And each cubic metre got cheaper, because it is compressed to 4 bar instead of 6. Together they take 44 % off the bill, for a third less force.

    Set Pin back to 6 and calculate once more before you save: lessons 3 and 4 start from this file.

  10. Save it

    File → Save as writes a .gf9 file holding the items, the connections, your input data and the results. Keep it — lessons 3 and 4 open it, and lesson 3 looks for a nozzle that gives the same force for a fraction of the air.

    If something went wrong on the way, the finished scheme of this lesson is examples/myFirstFile.gf9 — open it and compare it with yours row by row.

When it does not work

What you seeWhyWhat to do
Dragging on the sheet selects nothing A tree entry is still selected, so the sheet is in placing mode. Click the entry again to deselect it.
The connection will not start The point is taken — each point holds one connection. Right-click the point to release it, or use another one.
Calculate asks for a value in a dialog A green row of the pipe is empty — often Length. Type the value from the table in step 5.
The pipe has results, the compressor has none The pipe is not joined to the compressor. It is calculated on its own and gets a break badge on the sheet. Draw the connection again from the red outlet to the green inlet.
Qn is huge — millions A pressure field in Input parameters has lost its unit and reads as pascals. Check that the labels say (Bar); see the warning in step 6.
Q and Qn differ by more than 7 times Ambient temperature is not equal to the normal temperature, or Pin is not 6. Set both to 20 for this lesson.
Diameter turns into 0.0131 or similar The Length list is not in mm, or Input units is on Original. Go back to step 1.

Try this next