Lesson 11
Logger measurements
The audit of lesson 10 rests on figures typed from a nameplate and a watch. This lesson checks them against the site: a gauge and a flow meter on the network, a week of logger records from the compressor, and its measured power. Where the model and the site disagree, the audit says which of them to doubt.
Three kinds of measurement
| What | Where it goes | What the audit does with it |
|---|---|---|
| A single reading of a gauge or a flow meter | Audit measured of a sensor on the sheet | Compares it with the model within the accuracy of the instrument; a gauge below the model is held at its reading. |
| Logger records — power, pressure, flow over a week or two | The Measurement data window of the source | Loads, binds, shows and keeps them with the scheme. In this version they do not enter the calculation yet. |
| The mean electrical power of the compressor | Audit power and Audit hours of the source | Energy and money by measurement; the model is scaled to it. |
-
Start from the audit of lesson 10
Open
lesson10.gf9and save it at once aslesson11.gf9. It opens in audit mode with everything lesson 10 entered:Item Row Value COMP Audit pressure 6.5 bar COMP Audit capacity 2500 NL/min COMP Audit leak t load / t unload 6 / 54 s B1 Audit utilization 50 % B2 Audit utilization 30 % B2 Audit required pressure 4 bar Press Audit once and check COMP against lesson 10: Qn 1960.35, Qn average 995.68 NL/min, Leak share 25.04 %, Min audit pressure 6.1832 bar. If a figure differs, compare the rows of the table above first.
-
Put a flow meter and a gauge on the network
A site instrument goes on the sheet where it sits on the plant, in line, like the regulator of lesson 8: release a connection, place the item, join both sides.
Instrument Where Name A flow meter: VD 500 from Sensors (type VD 500in the filter)between COMP and P1, on the main line FMA pressure gauge: CS 16 from Sensors between P1 and T1, at the end of the main PGBoth are CS Instruments cards. CS 16 is an in-line pressure sensor with a 16 bar scale, accuracy 1 % of it. VD 500 is an insertion flow sensor for wet air: accuracy 1.5 % of the reading and nothing of the full scale, so its card has no Range. Rename them (F2) and press Audit. An instrument has no pressure loss: the results of lesson 10 stay as they were. Each gets its own audit rows:
Row Meaning Audit measured The reading: bar gauge for PG, a flow for FM. Audit range, Audit accuracy class Full scale and accuracy, % of the full scale. They appear only when the card has no Range or Accuracy row of its own — a site instrument that is not in the catalog. Audit load point When the reading was taken: 1— at maximum load (empty means 1),2— at average load. After the audit the row load_point repeats it as a result.PG has a Range and an Accuracy in its card, so it gets no Audit range or Audit accuracy class. FM gets Audit range: its card gives no full scale. Leave it empty — VD 500 is judged by its reading.
FM shows its Qn even before a reading: 1960.35 NL/min, all the air of COMP — the flow the model expects the meter to see.
The network of lesson 10 with a flow meter on the main line and a gauge at the end of the main. FM, just renamed, is still selected. -
Readings that agree with the model
The auditor walked the network at maximum load — both blow-offs on — and wrote down:
Item Audit measured PG 6.35 bar the gauge at the end of the main FM 1966 NL/min 118 Nm³/h on the meter's display; the row takes the unit of Qn Press Audit. Each instrument gets a Tolerance — how far the reading may be from the truth — and, when the model falls inside it, a row Audit: within accuracy with the difference reading − model:
Row PG FM Pin / Qn (model) 6.3755 bar 1960.35 NL/min Tolerance 0.16 bar 29.49 NL/min Audit: within accuracy −0.0255 bar 5.6524 NL/min Check by hand: the tolerance
The tolerance is u = Accuracy × Range + Accuracy reading × reading. For CS 16: 1 % × 16 bar = 0.16 bar. For VD 500: 0 + 1.5 % × 1966 = 29.49 NL/min. A site gauge without a card is taken as class 1.5 on the nearest standard scale not below 4/3 of the reading — 4/3 × 6.35 = 8.47, so 10 bar and 0.15 bar — and the note of the row marks every such assumption with ~.
Both agree: the model of lesson 10 describes this plant. That is the answer you hope for — and the one to have on file before anybody acts on the measures.
The gauge agrees with the model within its tolerance. -
A gauge that does not agree
Now suppose PG had read 6.0 bar. Type
6into its Audit measured and press Audit.The reading is 0.3755 bar below the model — more than the tolerance. A gauge below the model is believed: the audit holds that node at the reading, solves the network again, and everything downstream follows the gauge. The loss of pressure between the compressor and the gauge is real; the model now has to explain it.
Item Row Expected PG Pressure deviation −0.3755 bar alarm: the node is held at 6.0 PG Qn unaccounted alarm as a leak it would need more air than the compressor delivers; the value shown is only a ceiling, what the capacity leaves for it B1 Pressure deficit ≈ 0.06 bar B1 gets less than its 6 bar COMP Qn 2500 NL/min — at its capacity COMP Pout 6.21 bar — below its setting COMP Demand above capacity 0.29 alarm: bar below the setting To pull the end of the main down to 6.0 bar the model needs far more air through P1 than the compressor can give. COMP runs flat out at 2500 NL/min, its outlet falls to 6.21 bar, and the leaks, at lower pressures, shrink to 236 NL/min.
Qn unaccounted is the air the node would have to lose to fall to 6.0 bar — an equivalent leak between the compressor and the gauge. Here it is an alarm: the 25 mm main loses so little that only a huge leak could pull it down by 0.37 bar, more air than the compressor can give. So the drop is more likely an extra resistance — a half-closed valve, a crushed pipe, a dirty filter nobody drew on the scheme.
The flow meter settles it. FM still reads 1966 NL/min:
Row, FM Expected Audit: within accuracy 5.6524 NL/min the reading matches the flow without the gauge correction Diagnosis: resistance alarm: the flow did not grow by Qn unaccounted The meter on the main reads… Diagnosis Why the flow of the model before the gauge was held Diagnosis: resistance No extra air passes: something in the line eats the pressure. the flow after it, with Qn unaccounted Diagnosis: leak The extra air really goes through the meter and is lost before the gauge. The audit does not compare a gauge that reads above the model with anything downstream: it cannot hold a node higher than the air arriving there allows. It only reports Pressure deviation and, when the modelled loss to the gauge is larger than the tolerance, Loss upstream — the measured loss as a share of the modelled one. Here the model loses only 6.5 − 6.3755 = 0.12 bar on the way to PG, less than its 0.16 bar tolerance: the gauge could not tell that loss from zero, so PG gets no Loss upstream at all.
The flow meter decides: the drop at the gauge is a resistance, not a leak. This plant has no such resistance — it was a thought experiment. Set Audit measured of PG back to
6.35and press Audit: the alarms go and COMP is back at 1960.35 NL/min. -
Load a week of logger records
Single readings say how the plant stands at one moment. For a week the auditor leaves a data logger on the compressor: its power, the network pressure and the flow, every 30 seconds. Save lesson11-ald.csv — an export of an ALD logger, in American units: kW, psig, scfm.
Click COMP and double-click its row Audit measurement data — it reads no data - double-click to import. The Measurement data window opens. Press Add files... and choose the file. The Import logger file window opens for every file, even when it is recognised, so that you see how it will be read before anything enters the scheme:
Field Shows Why Profile ALD logger export Recognised by the header Timestamp,kW,psig,scfm.Delimiter, Decimal comma, point Header line 1 Order M/D/Y The file holds 2/17/2025: 17 cannot be a month, so the order is decided by the file, not guessed.Layout, Time column wide: one column per channel; Timestamp One row per moment, one column per channel, date and time in one column. Zone UTC+03:00, no DST — the zone of this computer The time stamps carry no zone of their own. For a logger from another time zone set its zone here. The table of columns at the bottom:
Column Use as Unit Bound to Sample min..max kW Power P kW K1 0..0 psig Pressure p psig Collector 0..0 scfm Flow Q scfm Collector −82..−82 A single compressor has one machine, so power goes to it; pressure and flow are measured on the collector — the pipe the compressor feeds. Sample min..max covers only the first lines, here the night before the first shift: the machine is off, the pressure is zero — and the flow reads −82 scfm.
Press Import. EasyCAS spots the −82 at once:
scfm: 100.0 % of the values are negative and 76.2 % are exactly -82. This looks like a constant subtracted in the logger or in the export (a stopped machine reads -82 instead of 0). Add b = 82 to this column, so that the stopped state reads 0?
Answer Yes. ALD exports really do this. The offset goes into the corrections of this file (a = 1, b = 82); the file itself is not changed.
The import window: how EasyCAS will read the file, before anything is loaded. -
Read the week
The Measurement data window now holds the file:
Table What to check Expected Files Period, Rows, Rejected, Profile 17.02.2025 00:00 – 24.02.2025 00:00; 20161; 0; ALD logger export Channels Quantity, Bound to, Coverage kW → K1; psig → Collector; scfm → Collector; 100 % Notes Analysis period 17.02.2025 00:00 – 24.02.2025 00:00 (whole weeks) Pressure and flow are drawn in the units of the Units tab — bar and NL/min — power in kW. Each channel has a band of its own, and the analysis period is shaded: one whole week from Monday, because the file covers one. Turn the mouse wheel to zoom into a working day, and the week reads like a story:
- the compressor runs from 07:00 to 15:00, Monday to Friday, and stands the rest of the time: 40 hours a week;
- while it runs, the power jumps between about 15 kW (loaded) and 4.5 kW (unloaded): a load/unload machine;
- the pressure saws between 6.0 and 6.5 bar: it unloads at 6.5 — the Audit pressure of lesson 10 — and loads again at 6.0;
- the flow swings with the blow-offs, never below the leaks.
The card row of COMP now reads 17.02-24.02.2025, 3 ch. The records are kept in
lesson11.gf9, compressed; the CSV file is not needed any more, but keep it for Re-import file....One week of the compressor: five shifts, power, pressure and flow on one time axis. What the records do — and do not do yet. In this version the logger records are loaded, bound, shown and stored. Statistics of the machines and the calibration of the model against them come in the next version; the notes of the window say so. Until then the bridge from the logger to the calculation is the next step: the measured mean power.
-
Turn the records into Audit power
Press Export hourly CSV... and save the file. It holds the hourly means of every channel, one row per hour and channel, in the units of the file:
timestamp;channel;value;unit 2025-02-17 07:00;kW;8.706…;kW
The channels keep the names and units of the logger —
kW,psiginpsi,scfm— and the correction b = 82 is already in the flow. The file is calledhourly_ID7.csvunless you name it otherwise.Open it in a spreadsheet (Data → From Text/CSV, delimiter semicolon, decimal point) and average the power over the hours the compressor ran:
=AVERAGEIFS(C:C, B:B, "kW", C:C, ">0"). Forty hours, mean 8.71 kW.Check: the logger meets the model
Average the flow the same way: 34.73 scfm while running. One scfm is 28.69 NL/min (101325 Pa against the 1 bar of Normal pressure), so 34.73 × 28.69 = 996 NL/min — and the audit of lesson 10 gave Qn average 995.68. Utilization, leaks and consumers were guessed in lesson 10; the logger says the guesses hold. The pressure averages 6.26 bar, the middle of the 6.0–6.5 band — what an accepted load/unload machine would give as Pout average (lesson 9).
Click COMP and fill:
Row Value Audit power 8.7 kW mean electrical power while running Audit hours empty 40 h a week × 48 weeks = 1920 h — the same as 8 h × 240 days of Input parameters Press Audit. COMP gets the energy by measurement, and the estimate of lesson 10 is scaled to it:
Row, COMP Before Now Unit Electricity consumption 22223 22223 kWh the estimate from Compressed air cost Spec power audit 8.738 kW/Nm³/min Audit power / Qn average Annual energy audit 17 MWh 8.7 kW × 1920 h Annual cost audit 2172 € at Electricity cost 0.13 €/kWh Power calibration 0.752 measured / estimated energy Annual energy calibrated 17 MWh Annual cost calibrated 2172 € Leak energy 5.6 4.2 MWh 25.04 % of the calibrated energy Leak cost 723 544 € Artificial demand energy 1.4 1.0 MWh Artificial demand cost 180 136 € Check by hand: the calibration
Without a machine, lesson 10 priced the air with Compressed air cost: 2889 € a year, that is 2889 / 0.13 = 22 223 kWh. The meter says 8.7 kW × 1920 h = 16 704 kWh. Their ratio, 16 704 / 22 223 = 0.752, is Power calibration: every energy and money figure of this source is multiplied by it — the leaks are 25.04 % × 16.70 MWh = 4.18 MWh and 25.04 % × 2172 € = 544 €. The specific power, 8.7 kW for 0.9957 Nm³/min, is 8.74 kW per Nm³/min — high, as it is for a load/unload machine that runs loaded only 40 % of the time.
The estimate from the price of air was a third too high: this plant makes its air cheaper than the 0.024 €/Nm³ of Input parameters says. Every saving of the audit is now counted at the measured energy — the measures in the Problems panel too (the lower setting is now worth 154 €/yr instead of 204), and, in lesson 12, the scenarios, which take the same calibration from this baseline.
Had the compressor run two shifts, the logger would have shown 80 hours a week: Audit hours 3840 would then set the year of this source, for the measured energy and for the estimate alike.
The compressor with its measured power: the model scaled to the meter. -
Save it
Save
lesson11.gf9. It keeps the readings, the logger week and the measured power. Lesson 12 applies the measures of lesson 10 in a scenario of their own and counts what they pay back — at the energy you have just measured.
When it does not work
| What you see | Why | What to do |
|---|---|---|
| No Audit measured row on the instrument | The scheme is in design mode, or the card is not a pressure or flow sensor. | Switch to Audit and press Audit; check Element of the card (Pressure or Flow). |
| Pressure deviation with “Reading above the compressor pressure” | A single compressor cannot give more than its setting. | Check the gauge (zero, scale) and Audit pressure. |
| “Gauge at the compressor outlet differs from Audit pressure” | The gauge sits on the same node as the compressor outlet, where the setting already holds the pressure. | The gauge reads the setting: correct Audit pressure. |
| Qn deviation on a flow meter | The reading is outside the tolerance: more air means a leak or a consumer missing downstream, less means the consumers take less. | Check Audit utilization, the drawn consumers and the leak test. |
| The import stops and asks for the order of day and month | All dates of the file are 1–12 and both readings run forward. | Choose Order and press Import again. |
| Measurement data is used in Audit mode only. | The scheme is in design mode. | Switch to Audit. |
| Model not calibrated | Audit power is set, but there is no energy of the model to compare it with. | Accept a machine in Compressor selection, or fill Compressed air cost and Electricity cost in Input parameters. |
Try this next
- Type
2500into Audit measured of FM, with PG at 6.0. The meter now agrees with the flow after the gauge was held: Diagnosis: leak, with the equivalent leak in Nm³/h. Set both back. - In the Measurement data window, drag over Tuesday's shift to set the analysis period by hand, then press Default period to get the whole week back.